Parameter

Range

Á¤°Ý Àü¾Ð

DC 5V

µ¿Àû Àü¾Ð ¹üÀ§

DC 4.65V ~ 5.5V

ÃøÁ¤ ¿Âµµ ¹üÀ§

30¡É ~ 40 ¡É

»ç¿ë ¿Âµµ ¹üÀ§

0¡É ~ 45 ¡É

SHUTTER

ACTIVE
( No Need Calibration )

PIXEL

RESOLUTION

80 x 60

SIZE

35um

RADIOMETRY

Á¤È®µµ

± 0.3 ¡É

º¸Áõ ¿µ¿ª

X : 70, Y : 50 ( PIXEL )

ÆÄÀå / ÆÄÀå´ë¿ª

LWIR / 8um ~ 14um

FOV(È­°¢)

50¢ª / 51.5¢ª(H) X 38.3¢ª(V)

ÀÎÅÍÆäÀ̽º

Micro 5pin USB

ÇÁ·¹ÀÓ¼Óµµ / ¿ÂµµºÐÇØ´É

30fps / <100mk(0.1¡É)

Áß·®

62g (¼¾¼­ 40g + case 22g)

Scene Dynamic Range

100¡É

 

ElijaBeth ¿­È­»óÄ«¸Þ¶ó ¼³Ä¡

Application (Viewer)

 

 

IR¼¾¼­ °ü·Ã ƯÇã

No

³»    ¿ë

¹ßÇà±â°ü

¹ßÇàÀÏÀÚ
(³â¿ùÀϷαâÀç)

À¯È¿±âÇÑ
(³â¿ùÀϷαâÀç)

ºñ°í

1

ÇÊ ÆÑÅÍ°¡ Çâ»óµÈ º¼·Î¹ÌÅÍ ¹× ¸¶ÀÌÅ©·Î º¼·Î¹ÌÅÍÀÇ Á¦Á¶¹æ¹ý

ƯÇãû

2017.04.25

2036.04.26

ƯÇãµî·Ï

2

¸¶ÀÌÅ©·Î º¼·Î¹ÌÅ͸¦ Æ÷ÇÔÇÏ´Â °øÀ¯ ¾ÞÄ¿ ±¸Á¶ÀÇ Àû¿Ü¼± ¼¾¼­

ƯÇãû

2017.09.01

2037.01.08

ƯÇãµî·Ï

3

Àû¿Ü¼± °ËÃâ±â

ƯÇãû

2017.11.29

2037.01.08

ƯÇãµî·Ï

4

ÇÊ ÆÑÅÍ°¡ Çâ»óµÈ º¼·Î¹ÌÅÍ ¹× ¸¶ÀÌÅ©·Î º¼·Î¹ÌÅÍÀÇ Á¦Á¶¹æ¹ý

ƯÇãû

2017.12.29

2037.02.27

ƯÇãµî·Ï

5

¼±Åýİ¢ °øÁ¤À» ÀÌ¿ëÇÑ ¸¶ÀÌÅ©·Î º¼·Î¹ÌÅÍ Á¦Á¶¹æ¹ý ¹× ÀÌ¿¡ µû¶ó Á¦Á¶µÈ ¸¶ÀÌÅ©·Î º¼·Î¹ÌÅÍ

ƯÇãû

2018.03.22

2037.09.27

ƯÇãµî·Ï

6

¸¶ÀÌÅ©·Î º¼·Î¹ÌÅÍ
±â¹Ý Àû¿Ü¼± °ËÃâ±â

ƯÇãû

2018.07.18

2038.04.01

ƯÇãµî·Ï

7

¸¶ÀÌÅ©·Î º¼·Î¹ÌÅÍ ¹× ¸¶ÀÌÅ©·Î º¼·Î¹ÌÅÍ Á¦Á¶ ¹æ¹ý

ƯÇãû

2019.11.01

 

ƯÇãÃâ¿ø

8

¹Ý»çÆÇ ±¸Á¶ÀÇ ºí¶óÀÎµå ¼¿, À̸¦ Æ÷ÇÔÇÏ´Â ¸¶ÀÌÅ©·Î º¼·Î¹ÌÅÍ ¹×
±× Á¦Á¶¹æ¹ý

ƯÇãû

2020.04.07

 

ƯÇãÃâ¿ø

9

Àû¿Ü¼± °¨Áö ¼¾¼­ ¸ðµâ ¹× Àû¿Ü¼± °¨Áö ¼¾¼­ ¸ðµâ Á¦ÀÛ ¹æ¹ý

ƯÇãû

2020.04.29

 

ƯÇãÃâ¿ø

 

 

ÀÎÁõÇöȲ (Certificate)

 

ElijaBeth ÅÂºí¸´PC ¼³Ä¡

 

 
 For the first quarantine caused by the COVID-19, Elij¥ábeth can detect high-temperature patientsin 0.5 seconds and sound a quick automatic alarm with its core technologies
 

 

 Automatic background removal
When the ambient temperature is measured higher than its subject due to its installation/use environment, this function can darken the peripheral part and exclude it form the measurement target for detecting a subject with a certain temperature or higher. It is useful when installing while looking outdoors.

 Temperature unit
It is set to Celsius by default. You can change it to Fahrenheit as needed.

 FPS(Frame Per Second)
This is the number of screens displayed per second. If the installed PC or tablet has  high specifications, you can set FPS up to 30fps. The higher it is, the smoother the image will look. The default value is 20 fps. 

 Signal Filter
This function removes noise on the temperature data (screen). When measuring in a static environment, using the LPF function enables you to make a relatively accurate measurement. You can select and use it according to your video preferences. LPF is the default value.

 


 Image Filter
This is an image processing filter function. Disabling this function can reduce the CPU usage, however, the image can not be smooth. You can use it according to your video preferences.

 Warning
If you activate this function, an alarm sounds when it detects a subject with a specified temperature or higher. The set temperature is also displayed at the top of the main screen. 

 Auto Save
If you activate this function, the screen image is automatically saved and an alarm sounds when it detects a subject with a specified temperature or higher. Images are basically saved in "My Documents", and if you want to change folder, you can set another folder by clicking the tab on the lower menu.

 Measurement Mode
It determines the range and color of the lowest/highest temperature on the screen. People (33~35¡É), user is designated randomly, dynamic is changed in real time based on the lowest and highest points of the current screen (scene). You can use it according to your video preferences.

 Screen Quality Improvement 
A menu has been added to improve thermal image quality on high-performance PCs (i3 or higher). The picture will be displayed smoothly.  ¡Ø We recommend using it on a high-performance PC 

 

 Emissivity Value by Temperature Ranges
The default emissivity value at factory is 1.0.Elijabeth adds User-specified emissivity function to cope with various installation environments. This can be used when you want to display higher temperature value than the surface measurement temperature or when using a cooling/heater at a specific time.

Based on the reference environmental temperature measured by the sensor, you can correct the emissivity of a specific temperature range and click the save button on the right

If the display temperature of the person measured at the current environmental temperature is low, decrease the emissivity value little by little and save it

After applying the emissivity, if you need to use a high/low temperature due to the environment or need, you can set the temperature to the range you want with its Offset function.